Automatic Nucleic Acid Extractor YR01871

Automatic Nucleic Acid Extractor YR01871 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.
The Automatic Nucleic Acid Extractor YR01871 is at the forefront of nucleic acid extraction technology. This sophisticated automated system employs cutting-edge rotary mixing technology (RMT) to significantly minimize aerosol generation and reduce the risk of cross-contamination. Designed to be compatible with both deep 96-well plates and six-tube strips, it offers unmatched flexibility with the ability to process 1 to 96 samples per cycle. The YR01871 ensures precision and efficiency in every experiment, making it an invaluable asset for any laboratory setting.
Market Price
The market value for nucleic acid extraction systems like the Automatic Nucleic Acid Extractor YR01871 typically ranges from $30,000 to $31,500 USD. This price reflects the advanced features and reliability that such high-performance equipment offers. For an exact quote tailored to your needs, head over to our platform, Kalstein Plus, to generate an automatic quotation.
Frequently Asked Questions
How many samples can the YR01871 process at once?
The YR01871 can efficiently process 1 to 96 samples per cycle, making it ideal for laboratories with varying throughput requirements.
Is the system compatible with different consumables?
Yes, it is compatible with 96-deep-well plates and customized six-strip tubes.
Advantages and Disadvantages
Among its many advantages, the YR01871 offers high throughput, reduced reagent waste, and exceptional precision thanks to its rotary mixing technology. The intuitive 7-inch LCD touch screen simplifies operation. A potential disadvantage might be the initial investment, though the system's efficiency and reliability can outweigh the cost over time.
Product Use in the Field
The YR01871 is instrumental in both research and clinical settings for extracting high-quality nucleic acids. Its advanced contaminant control features, like the HEPA filtration and UV disinfection module, ensure a safe and clean environment, enhancing the accuracy and success of subsequent experiments.
Recommendations
To ensure longevity and optimal performance, it is recommended that users follow scheduled maintenance checks, utilize appropriate consumables, and regularly update software protocols. For more guidance, reach out via Kalstein Plus for expert support.
Features
* Automatic motor-driven lid operation
* Up to 1,000 programmable storage options
* User-friendly full-color touch screen interface
* Negative pressure exhaust system with HEPA filtration
Technical Specifications
| Model | YR001871 |
| Throughput | 1-96 |
| Reaction Volume | 30-1000uL |
| Sample Volume | 200uL |
| Compatible Consumables | 96-deep-well plates |
| customized 6 strip tube | |
| Inter-well Extraction Difference | CV ≤3% |
| Rotational Speed | ≤3000rpm |
| Heating Temperature | Lysis heating: room temperature to 120°C |
| Elution heating: room temperature to 120°C | |
| Mixing Method | Rotary mixing |
| Operation Mode | 7-inch full-color LCD touch screen operation |
| Program Storage | Up to 1000 programs can be storaged |
| Protocol Management | Flexible to create, edit and delete protocols |
| Automatic Control | Motor-driven automatic opening and closing of the experiment cabinet |
| Magnetic Bead Residue | ≤1% |
| Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
| Contamination Control | Negative pressure HEPA exhaust filter module; |
| Built-in UV disinfection module | |
| Connection Port Type | USB port |
| Weight | 45kg (net) |
| Instrument Dimensions | 510mm*490mm*480mm (W*L*H) |
| Power Supply and Power Consumption | AC 100V-240V, 50/60HZ; 600VA |
Technical specifications
| Weight | 54 kg |
|---|---|
| Manufacturer | Kalstein |
Frequently asked questions
How to know the prices of Automatic Nucleic Acid Extractor YR01871?
To know the price of Automatic Nucleic Acid Extractor YR01871, please send us an email with your request through the contact form AQUI.
What are the delivery times for Automatic Nucleic Acid Extractor YR01871?
Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.
How to make a purchase of Automatic Nucleic Acid Extractor YR01871?
You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.
How does the warranty work for Automatic Nucleic Acid Extractor YR01871?
All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.
Can I request a quote online for Automatic Nucleic Acid Extractor YR01871?
Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.