Description
The Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is an advanced instrument developed independently by Kalstein, renowned for its independent intellectual property rights. Featuring a 7-inch TFT capacitive touch screen display and a dynamic optical geometry that includes reflective d/8 and transmissive d/0 geometry (with options to include or exclude UV), this spectrophotometer is ideal for accurate color measurement in research and development as well as laboratory environments. It offers a stable, precise color analysis with innovative features like a built-in temperature sensor, customizable measuring apertures, and powerful PC software to enhance its functionality.
Market Price
In the market for spectrophotometers, the price range can vary significantly based on the model and features. For a premium device like the YR05475, prices typically fluctuate between $10,000 and $11,200. This pricing reflects its high configuration and advanced technology, making it a worthwhile investment for industries requiring precise color analysis and transmission solutions.
Frequently Asked Questions
- What industries benefit most from the YR05475? The YR05475 is widely used across various sectors, including plastics, electronics, paint and ink, printing, garments, leather, paper, automotive, medical, cosmetics, and food.
- Can the spectrophotometer measure UV light? Yes, the device comes with a built-in 400nm cut-off, making it highly effective for UV measurement.
- What is the lifespan of the xenon lamp? The xenon lamp in the YR05475 has a lifespan of over five years or more than three million measurements.
Advantages and Disadvantages
Among its advantages, the YR05475 offers high configuration hardware and a wide range of measurement modes, making it versatile for various applications. Its large data storage capacity and Bluetooth connectivity are additional benefits. However, potential users should consider the learning curve associated with its advanced features and the initial investment cost as possible disadvantages.
Field Use
In practical scenarios, the YR05475 is utilized for precision color analysis and transmission, making it indispensable in laboratories and industrial settings. Its ability to switch between multiple measuring apertures and measure different spectrums efficiently allows researchers and technicians to achieve accurate results in less time.
Recommendations
To ensure optimal performance and longevity of your YR05475 device, regular calibration and maintenance checks are recommended. Users are encouraged to utilize the built-in PC software for extended functionalities and to consider additional accessories, such as the micro-printer, for enhanced operations. For a customized quote, access Kalstein Plus to explore seamless service options and take your research capabilities to new heights.
Features
- 7-inch TFT capacitive touch screen display
- Bluetooth 2.1 connectivity and concave grating
- Accurate Lab value measurement for precise color transmission
- Customizable measuring apertures with auto-identification
- Built-in temperature sensor for precision
- Multiple measurement modes and large data storage
- Extended functionalities via PC software
Technical Specifications
Model | YR05475 (Pulsed xenon lamp) |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE |
Transmittance: SCI&SCE | |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7″ TFT Capacitive Screen-touch Display |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Notes: The specifications are subject to change without notice. |