Description
The Electrolyte Analyzer YR06396 // YR06406 is a state-of-the-art device engineered to deliver precise and rapid measurements of electrolytes across various sample types, including serum, plasma, whole blood, and diluted urine. This analyzer is outfitted with sophisticated automatic electric potential tracking and correction software, ensuring stable and reliable performance. It effectively detects and filters micro-bubbles to prevent blockages, thereby guaranteeing accuracy in every analysis. The system’s real-time diagnostics and automatic detection of waste liquid, coupled with timely alarms, enhance operational safety, making this device an invaluable asset in busy clinical settings. With capabilities like automatic calibration and two-point adjustments for slope and intercept, the Electrolyte Analyzer YR06396 // YR06406 optimizes accuracy effortlessly.
Market Price
The Electrolyte Analyzer YR06396 // YR06406 is priced between $2000 and $7000 USD, contingent on additional features and supplier options. This price range reflects its cutting-edge technology and precision engineering. For those interested in acquiring this high-quality equipment, a personalized quote suited to your laboratory’s unique requirements is easily obtainable via the Kalstein Plus platform. Here, potential buyers can seamlessly generate an automatic quote, ensuring an optimized investment tailored to specific operational needs.
Frequently Asked Questions
- What types of samples can the YR06396 // YR06406 analyze?
This analyzer can measure electrolytes in serum, plasma, whole blood, and diluted urine samples. - What is the storage capacity of the YR06396 // YR06406?
The device can store up to 10,000 test results. - How long does it take to perform a measurement?
The YR06396 // YR06406 performs measurements in less than 30 seconds.
Advantages and Disadvantages
Advantages:
- High precision and rapid measurement capabilities.
- Interactive menu with real-time display.
- Advanced bubble detection and flushing methods.
- Ample result storage capacity.
- Equipped with power failure protection.
Disadvantages:
- Significant initial cost, which may be substantial for smaller laboratories.
- Regular maintenance is required for optimal performance.
Field Use
The YR06396 // YR06406 analyzer is perfectly suited for clinical and hospital laboratories that necessitate quick and accurate electrolyte analyses. Its multi-sample handling capability combined with its efficient design makes it ideal for high-demand environments. Its rapid measurement processing and ease-of-use ensure consistent and reliable results.
Recommendations
To extend the lifespan and enhance the performance of the Electrolyte Analyzer YR06396 // YR06406, adherence to the manufacturer’s maintenance and calibration guidelines is crucial. Periodic inspections and thorough cleaning are recommended to avoid buildups that could compromise measurement accuracy. Additionally, ensuring that laboratory personnel are well-trained in operating the instrument will facilitate efficient use and prolong its operational durability.
For laboratories seeking to elevate their capabilities with a reliable and precise electrolyte analysis device, the Electrolyte Analyzer YR06396 // YR06406 represents an excellent choice. Visit the Kalstein Plus platform today to request a personalized quotation or to generate an automatic quote. Optimize your laboratory performance by investing in this advanced technology.
Technical Specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG |
K Na Cl iCa nCa TCa pH Mg Li
|