Technical Glossary and Key Terminology for the YR06220 Infant Phototherapy Unit
The YR06220 Infant Phototherapy Unit is a crucial device in the treatment of neonatal jaundice, providing effective phototherapy to reduce bilirubin levels in infants. This article presents a technical glossary and key terminology related to the YR06220 model, aiming to deepen the understanding of its operation, specifications, and applications.
Overview of the YR06220 Infant Phototherapy Unit
The YR06220 is designed for clinical settings where precise and effective treatment of jaundice in infants is required. This device utilizes specific wavelengths of light to aid in the breakdown of bilirubin, making it essential for neonatal care.
Technical Specifications of the YR06220
| Model | YR06220 |
|---|---|
| Bilirubin Radiancy (40 cm) | 3750μw/cm2 (62.5μ w/cm2/nm) |
| Bilirubin Radiancy (50 cm) | 3200μw/cm2 (53mw/cm2/nm) |
| Lighting Intensity | 33%, 67%, 100% |
| White Light | Yes |
| Power | ≤60VA |
| Wave Length | 400nm~550nm |
| Radiant Space | 400×250mm |
| Radiant Uniformity | 0.4 |
| Therapy Time Set | 0-99h59m |
| Height Range | 1350mm~1650mm |
Glossary of Key Terms Related to the YR06220
| Term | Definition |
|---|---|
| Bilirubin | A yellow compound that occurs in the normal catabolic pathway that breaks down heme in vertebrates. Its accumulation in the blood leads to jaundice. |
| Phototherapy | A treatment method using specific wavelengths of light to reduce bilirubin levels in jaundiced infants. |
| Radiancy | The amount of light energy received per unit area, crucial for determining the effectiveness of the phototherapy. |
| Intensity | The power per unit area of light emitted by the device, adjustable to meet treatment needs. |
| Wave Length | The distance between successive peaks of a wave, important for targeting bilirubin breakdown during phototherapy. |
| Uniformity | The consistency of light intensity across the treatment area, ensuring all parts of an infant are adequately treated. |
| White Light | Light that contains all colors of the spectrum, which can aid in examination during treatment. |
| Operating Height | The adjustable height range of the YR06220, allowing for optimal positioning relative to the infant. |
| Control System | The programmable mechanism that allows for the adjustment of lighting intensity and therapy duration. |
| Therapy Time | The duration for which phototherapy is administered, set according to the infant's needs. |
Frequently Asked Questions
What is the primary function of the YR06220 Infant Phototherapy Unit?
The primary function of the YR06220 Infant Phototherapy Unit is to provide effective treatment for neonatal jaundice by utilizing specific wavelengths of light to break down excess bilirubin in an infant's blood.
How does the adjustable height feature benefit the usage of the YR06220?
The adjustable height feature allows healthcare professionals to position the YR06220 optimally based on the infant's size and needs, ensuring effective treatment and ease of access for caregivers.
What are the lighting intensity options available on the YR06220?
The YR06220 offers three settings for lighting intensity: 33%, 67%, and 100%. This feature lets clinicians customize treatment to the specific requirements of the infant.
What is the significance of bilirubin radiancy levels in the YR06220?
Bilirubin radiancy levels, measured at distances of 40 cm and 50 cm, indicate the effectiveness of the unit in delivering the necessary light energy to reduce bilirubin levels. Proper radiancy ensures adequate treatment.
How can healthcare professionals ensure the YR06220 is functioning correctly before use?
Healthcare professionals can ensure functionality by performing initial calibration, checking the display for error codes, and confirming that the device is operating within the specified parameters before treatment begins.
Are there any special requirements for the environment where the YR06220 is used?
Yes, the YR06220 should be used in an environment that meets specific temperature and humidity levels to ensure optimal performance and safety for the infant.
How often should the YR06220 be serviced to maintain its effectiveness?
Regular servicing is recommended based on the manufacturer's guidelines, typically including checks on the light source, control systems, and overall functionality to ensure continued effectiveness in treating jaundice.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.