Technical Glossary and Key Terminology for the YR06221 Infant Phototherapy Unit
The YR06221 Infant Phototherapy Unit is a specialized device designed for treating neonatal jaundice through effective bilirubin phototherapy. Understanding the technical terminology associated with this unit is crucial for efficient operation and maintenance. This article will present key terms, their definitions, and how they relate to the usage of the YR06221.
Key Technical Terms Related to YR06221
| Term | Definition |
|---|---|
| Bilirubin | A yellow compound formed in the liver by the breakdown of red blood cells, which can cause jaundice in infants if elevated. |
| Phototherapy | A treatment method that uses light to reduce bilirubin levels in jaundiced infants. |
| LED Light | Light-emitting diode technology used in the YR06221 to provide effective phototherapy with minimal heat. |
| Bilirubin Radiancy | The intensity of light emitted by the unit, measured in μw/cm2, crucial for effective treatment. |
| Wave Length | The distance between successive peaks of a wave, relevant for determining the effectiveness of light in bilirubin breakdown. |
| Radiant Uniformity | A measure of how evenly light is distributed across the treatment area, essential for consistent therapeutic outcomes. |
| Therapy Time Set | The programmable time duration for phototherapy treatment, adjustable from 0 to 99 hours and 59 minutes on the YR06221. |
| Control System | The programmable component of the unit that manages lighting intensity and therapy duration. |
| Height Adjustment | The capability to adjust the height of the unit from 1350mm to 1650mm to accommodate different treatment setups. |
| Power Consumption | The maximum power used by the unit, rated at ≤60VA, indicating efficiency in energy use. |
| White Light Feature | A functionality of the unit that allows the use of white light for general examination and assessment of the infant. |
Understanding the YR06221's Technical Features
To effectively use the YR06221, operators should be familiar with the specific features and specifications of the unit:
| Specification | Detail |
|---|---|
| Model | YR06221 |
| Bilirubin Radiancy (40cm) | 3750μw/cm2 (62.5μw/cm2/nm) |
| Bilirubin Radiancy (50cm) | 3200μw/cm2 (53mw/cm2/nm) |
| Lighting Intensity | 33%, 67%, 100% |
| White Light | Yes |
| Power | ≤60VA |
| Wave Length | 400nm~550nm |
| Radiant Space | 400×250mm |
| Radiant Uniformity | >0.4 |
| Therapy Time Set | 0-99h59m |
| Height Range | 1350mm~1650mm |
Frequently Asked Questions
What is the purpose of the YR06221 Infant Phototherapy Unit?
The YR06221 is specifically designed to treat neonatal jaundice in infants by using light therapy to break down elevated levels of bilirubin in the blood, thus preventing complications associated with jaundice.
How does the lighting intensity affect the treatment of jaundice?
Lighting intensity is critical in phototherapy as it influences the efficacy of bilirubin breakdown. The YR06221 offers adjustable settings (33%, 67%, 100%) to optimize treatment based on the infant’s needs and response.
What are the recommended bilirubin radiancy levels for effective treatment?
For optimal treatment, the YR06221 should provide a bilirubin radiancy of 3750μw/cm2 at 40cm and 3200μw/cm2 at 50cm to ensure effective breakdown of bilirubin.
How can I determine if the YR06221 is functioning correctly?
Regular checks on the LCD display, which indicates accumulated operating time and current time, along with ensuring the light settings are appropriately configured, will help confirm the functionality of the unit.
What are the common maintenance practices for the YR06221?
Maintenance includes regular cleaning of the unit, checking for any errors or abnormal readings, and ensuring the light components are functioning as expected. Following the manufacturer's maintenance schedule is also crucial.
Can the YR06221 be used in various clinical settings?
Yes, the YR06221 is versatile and can be utilized in hospitals, clinics, and neonatal care centers, making it suitable for different healthcare environments focused on treating jaundice.
Where can I request a quote for the YR06221?
Interested parties can request a quote for the YR06221 through our dedicated sales channels, providing an opportunity to discuss pricing and specifications in detail.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.