LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675

LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675 — Kalstein laboratory equipment with technical specifications, advanced features, and certified professional solutions for scientific use.
Market Price
In the current market, autoclaves with similar specifications are typically priced between $7,800 and $8,600. These devices are an essential investment for maintaining sterile environments in medical and laboratory settings. To obtain an accurate quote tailored to your needs, we recommend visiting our platform, Kalstein Plus, for a quick and easy quotation experience.Frequently Asked Questions
- What types of instruments can be sterilized in this autoclave? The autoclave accommodates a variety of instruments, including packed and unpacked, dressings, and solids; it also supports type A and B hollow instruments, regardless of having multi-apertures or inset pipes.
- Is the device easy to operate? Yes, it features a user-friendly LCD interface and automatic controls, making the sterilization process straightforward.
- What happens if the water runs out during a cycle? The autoclave is equipped with a water level cutoff sensor, which stops operation immediately if water shortage is detected.
Advantages and Disadvantages
Advantages: This autoclave offers unparalleled efficiency with a precise microprocessor control, ensuring top-notch sterilization. Its built-in printer enhances record-keeping for compliance purposes. Safety features such as safety interlock doors and automatic shut-off offer peace of mind. Additionally, its flexible programming offers versatility for various sterilization needs. Disadvantages: While the initial investment is substantial, the long-term benefits of reduced contamination risks and regulatory compliance often justify the cost. The autoclave requires stable electric power and a careful maintenance routine to ensure longevity.Product Usage in the Field
The YR05673 // YR05675 is primarily used in medical facilities, laboratories, and research institutions for sterilizing surgical instruments, laboratory glassware, biohazardous waste, and other materials that require a sterile environment. Its efficient design allows for quick cycle turnovers, essential in high-demand environments. With its vacuum drying capability, it ensures instruments are dry and ready for immediate use post-sterilization.Recommendations
To optimize performance, ensure regular maintenance and calibration according to manufacturer guidelines. Always use the device in environments with stable voltage and conducive ambient temperatures. Performing routine checks and recording cycle results through the built-in printer assists in maintaining a thorough sterilization log, which is vital for auditing and quality assurance.Features
- Microprocessor-controlled with LCD display
- Pulsating vacuum drying with less than 0.2% residual moisture
- Four pre-set and customizable programs
- High-quality stainless steel construction
- Integrated printer for complete cycle documentation
- Advanced safety interlock and protection features
Technical Specifications
| Model | YR05673 | YR05674 | YR05675 |
| Max. pressure | 0.23Mpa | ||
| Working pressure | 0.22Mpa | ||
| Max. temperature | 136℃ | ||
| Working temperature | 134℃ | ||
| Working temperature range | 105 – 134℃ | ||
| Vacuum rate | -0.081Mpa | ||
| Sterilization time | 0 – 99 min | ||
| Drying time | 0 – 99 min | ||
| Accuracy of temperature | 0.1℃ | ||
| Heat average | ≤± 1℃ | ||
| Type | Vertical Pulsating Vacuum Autoclave | ||
| Class | Class B | ||
| Control | Microprocessor | ||
| Door | Hand wheel type quick open door | ||
| Display | LCD display | ||
| Drying system | Vacuum drying | ||
| Vacuum pump | Built-in | ||
| Steam generator | Built-in | ||
| Sterilization program | Pre-set program + User-defined program + Test program | ||
| Water tank | Yes | ||
| Printer | Yes | ||
| Sterilization basket | 2 PCS | ||
| Language | English | ||
| Voltage | 220-240V, 50/60Hz, single-phase | ||
| Chamber Size(mm) | 50L / Ø340×550 | 80L / Ø420×600 | 100L / Ø440×650 |
| Outer Size(mm) | 660×460×1160 | 700×520×1250 | 700×520×1250 |
| Packing Size(mm) | 820×600×1400 | 820×620×1450 | 820×620×1450 |
| G.W. / N.W. | 120/100 kg | 172/142 kg | 176/146 kg |
Technical specifications
| Manufacturer | Kalstein |
|---|
Available models
Frequently asked questions
How to know the prices of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?
To know the price of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675, please send us an email with your request through the contact form AQUI.
What are the delivery times for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?
Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.
How to make a purchase of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?
You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.
How does the warranty work for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?
All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.
Can I request a quote online for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?
Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.