Kalstein

Laminar Air Flow Clean Bench YR05728

SKU:YR05728 · By Kalstein

Category:Horizontal laminar flow cabinet

Laminar Air Flow Clean Bench YR05728

Laminar Air Flow Clean Bench YR05728 — Kalstein laboratory equipment with technical specifications, advanced features, and certified professional solutions for scientific use.

The Laminar Air Flow Clean Bench YR05728 is a state-of-the-art piece of equipment designed to provide a clean and sterile working environment. Its advanced features, including an arbitrary positioning sliding door system and a digital LCD control interface, ensure ease of use and efficiency. The cold-rolled plate shell is electrostatically sprayed, while the work surface is made from corrosion-resistant SUS304 brushed stainless steel, making it both durable and easy to clean. With a vertical quasi-closed tabletop and a downward airflow air curtain, this bench effectively prevents external air intrusion, maintaining the cleanliness of the operation area. Additionally, it is equipped with a HEPA high-efficiency air filter, complemented by a primary filter for preliminary filtration, which effectively prolongs the life of the high-efficiency filter.

Market Pricing

The price of laminar air flow clean benches can vary widely based on features, efficiency, and brand. The market price range for a product like the Laminar Air Flow Clean Bench YR05728 generally falls between $1,500 and $2,300. This variability allows institutions to choose a model that suits their budgetary constraints while still fulfilling their operational needs.

Frequently Asked Questions

What is the main purpose of the Laminar Air Flow Clean Bench YR05728? The primary use of this clean bench is to maintain a sterile working environment by preventing contamination from particulate matter and microorganisms.

How does the HEPA filter work? The high-efficiency particulate air (HEPA) filter captures at least 99.97% of airborne particles that are 0.3 microns or larger, providing an optimal level of cleanliness for sensitive applications.

Advantages and Disadvantages

This model stands out due to its user-friendly design and effective contamination prevention. Its advantages include a corrosion-resistant design, efficient HEPA filtration, and ease of operation. However, potential disadvantages may include a higher upfront cost and regular maintenance requirements to ensure optimal performance.

Product Use in the Field

The Laminar Air Flow Clean Bench YR05728 is commonly utilized in laboratories, hospitals, and research facilities. It is ideally suited for applications that require a contaminant-free environment such as tissue culture, microbiology studies, and other sensitive experiments.

Recommendations

To ensure the longevity and effectiveness of the Laminar Air Flow Clean Bench YR05728, it is recommended to perform regular maintenance checks, replace filters as needed, and adhere to the manufacturer’s guidelines for usage. For even more convenience, consider requesting a quote or generating an automatic quote through Kalstein Plus to streamline your procurement process.

Features

  • Arbitrary positioning sliding door system.
  • Cold-rolled plate shell with electrostatically sprayed surface.
  • Corrosion-resistant SUS304 brushed stainless steel work surface.
  • Interlocked lighting and sterilization systems with UV timing function.
  • Digital LCD control interface for user-friendly operation.
  • Vertical quasi-closed tabletop with downward flow air curtain.
  • Equipped with HEPA high-efficiency air filter and primary filter.

Technical Specifications

ModelYR05728
Cleanliness LevelClass 100@≥0.5μM (US Federal 209E)
Number of Colonies≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed0.25~0.45m/s
Noise≤62dB(A)
Vibration half peak≤5μM(x、y、z direction)
Illuminance≥300Lx
Power SupplyAC single phase 220V/50Hz
Maximum Power490W
Weight90kg
Work area size

W1×D1×H1

880×510×580

1040×690×1600

DimensionsSingle/Single
High efficiency filter specification and quantity850×565×50

Technical specifications

Weight210 kg
ManufacturerKalstein

Video Laminar Air Flow Clean Bench YR05728

Frequently asked questions

How to know the prices of Laminar Air Flow Clean Bench YR05728?

To know the price of Laminar Air Flow Clean Bench YR05728, please send us an email with your request through the contact form AQUI.

What are the delivery times for Laminar Air Flow Clean Bench YR05728?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Laminar Air Flow Clean Bench YR05728?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Laminar Air Flow Clean Bench YR05728?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Laminar Air Flow Clean Bench YR05728?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.