Kalstein

Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05644-1: Buying Criteria and Validation

By Kalstein · Published on:

Category:articulos-de-productos

Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05644-1: Buying Criteria and Validation

Explore the buying criteria and validation for the Horizontal Pulsating Vacuum Autoclave YR05644-1, a state-of-the-art laboratory device featuring advanced cont

Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05644-1: Buying Criteria and Validation

Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05644-1: Buying Criteria and Validation

The Horizontal Pulsating Vacuum Autoclave YR05644-1 is a remarkable asset in modern laboratory settings, designed to provide efficient sterilization processes. This article will delve into the product description, market price, frequently asked questions, pros and cons, field usage, and recommendations for this specific autoclave model.

Product Description

The YR05644-1 autoclave is a horizontal pulsating vacuum sterilizer that boasts an array of features tailored for optimal performance in sterilization. Its notable characteristics include:

  • Type: Horizontal Pulsating Vacuum Autoclave
  • Door: Single/Dual Door options available
  • Class: Class B sterilizer
  • Vacuum system: Includes pre-vacuum and post-vacuum stages
  • Control system: PLC + HMI + Printer
  • Display: 7-inch color LCD touchscreen
  • Steam generator: Built-in steam generator
  • Safety: Safety interlocked door with shield and switch
  • Loading: Sterilization tray for easy loading
  • Water reservoir: Included
  • Drying function: Vacuum drying capability
  • Printer: Built-in printer for documentation
  • Language: English interface
  • Voltage: 380V, 50/60Hz

Incorporating advanced technology, the autoclave features a dual-layer cylindrical design allowing steam to warm the chamber effectively. The automatic processes for water addition, pulsed vacuum, heating, sterilization, drying, venting, and printing enhance user experience and efficiency.

Additionally, it includes a high-quality vacuum pump to ensure optimal steam saturation by effectively removing air. Unique procedures for pulse vacuum drying result in instrument residual humidity below 0.2%. Several safety features are integrated, including overheating and overpressure protections, ensuring the safety of the operator and the device.

FeatureDetails
Design Pressure-0.1/0.25Mpa
Design Temperature139℃
Working Temperature Range105℃-136℃
Maximum Working Pressure0.23Mpa
Sterilization Time Range0-99 minutes
Drying Time Range0-99 minutes
Vacuum Rate-0.081Mpa
Temperature Precision0.1℃

Market Price

The market price for the YR05644-1 Horizontal Pulsating Vacuum Autoclave is approximately $6,667 USD. Prices may vary based on suppliers and regions, so it is advisable to verify with authorized distributors. When considering the purchase, potential buyers should factor in the cost-benefit ratio associated with the efficiency, reliability, and safety features of this advanced sterilization equipment.

Frequently Asked Questions

What is the capacity of the YR05644-1 autoclave?

The YR05644-1 autoclave has varying chamber sizes, with capacities ranging from 100L to 300L depending on the configuration, suitable for different sterilization needs.

How does the autoclave ensure safety during operation?

The autoclave features multiple safety mechanisms including a safety interlocked door system, temperature and pressure safety controls, and an automatic release valve that opens under excessive pressure or temperature.

Can the autoclave accommodate different types of sterilization loads?

Yes, the YR05644-1 is designed to accommodate various types of loads, including solid instruments, hollow devices, and porous materials, making it versatile for laboratory applications.

What is the drying process like in the YR05644-1?

The autoclave employs a unique pulse vacuum drying procedure that minimizes residual moisture, achieving less than 0.2% humidity in sterilized instruments, ensuring optimal sterilization effectiveness.

How often does the autoclave require maintenance?

Regular maintenance is recommended for optimal performance, typically every six months or as determined by the manufacturer's guidelines. Proper upkeep ensures longevity and reliability of the equipment.

Is there a warranty on the YR05644-1 autoclave?

Details about warranty may vary by supplier, but standard warranties typically cover parts and labor for a specific period. Always check the warranty terms before purchase.

For those interested in acquiring this advanced autoclave system, it is advisable to request a quote to explore pricing options and availability.

Pros and Cons

Understanding the advantages and disadvantages of the YR05644-1 Horizontal Pulsating Vacuum Autoclave can be crucial for making an informed purchasing decision.

Pros

  • High-quality construction ensuring durability
  • Advanced safety features for operator protection
  • Efficient sterilization and drying processes
  • User-friendly touchscreen interface for easy operation
  • Built-in printer for documentation of sterilization cycles

Cons

  • Higher initial investment compared to standard autoclaves
  • Requires regular maintenance to ensure optimal functioning
  • Training may be necessary for users unfamiliar with advanced autoclave technology

Field Usage

The Horizontal Pulsating Vacuum Autoclave YR05644-1 is widely used across various fields, including:

  • Healthcare: Hospitals and clinics utilize the autoclave for sterilizing surgical instruments and medical devices.
  • Laboratories: Research facilities rely on this autoclave for sterilizing microbiological media and laboratory glassware.
  • Dental Offices: Dental practices use this autoclave to sterilize tools and equipment.
  • Pharmaceuticals: Pharmaceutical companies employ autoclaves in the production of sterile medicines.

Its versatility makes the YR05644-1 an essential piece of equipment in any environment requiring effective sterilization protocols.

Recommendations

When considering the YR05644-1 autoclave for your laboratory, it is advisable to:

  • Evaluate your specific sterilization needs and select the appropriate model based on chamber size and features.
  • Review operational procedures to ensure staff training on the autoclave's functionalities and safety protocols.
  • Establish a maintenance routine to prolong the life of the autoclave and maintain consistent performance.
  • Consult with manufacturers or authorized distributors for the best pricing and service options.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05644-1 with all specifications, dimensions, accessories and quote options.
View product datasheet →