The YR06545 biosafety cabinet is a state-of-the-art solution designed to ensure the safety of personnel, products, and the environment. With its negative pressure system, it effectively prevents any leaks, providing a safe working environment. This cabinet operates on a principle of 70% internal circulation and 30% external exhaust, making it efficient for various laboratory applications.
Product Description
The YR06545 model is constructed from high-quality cold-rolled steel, ensuring durability and strength. The work surface is made from a corrosion-resistant physico-chemical plate that can withstand various laboratory conditions. Precision CNC laser cutting and an electrostatic epoxy resin surface treatment enhance its longevity and usability.
This model integrates smart control with an intuitive LCD touchscreen, allowing users to easily understand and monitor its operational status. Compliance with international standards ISO14644.1 Class 5 (equivalent to US Federal standard 209E, Class 100) ensures that this cabinet meets stringent cleanliness requirements.
The YR06545 is equipped with a high-efficiency German EBM motor designed for high airflow and low energy consumption, optimized to minimize turbulence and ensure uniform airflow. The filtration system includes external HEPA filters and ULPA filters, providing excellent air purity and safety for sensitive applications.
Market Price
The YR06545 biosafety cabinet is competitively priced at $2,270.00 USD. Below is a technical comparison highlighting the specifications of the YR06545 alongside other models:
| Specification | YR06543 | YR06544 | YR06545 | YR06546 | YR06547 |
|---|---|---|---|---|---|
| Package Size (mm) | 110*100*140 | 130*100*140 | 160*100*140 | 190*100*140 | 210*100*140 |
| External Size (mm) | 900*760*2250 | 1100*760*2250 | 1300*760*2250 | 1500*760*2250 | 1800*760*2250 |
| Internal Size (mm) | 740*600*600 | 940*600*600 | 1140*600*600 | 1340*600*600 | 1640*600*600 |
| Work Surface | SUS304# Brushed Stainless Steel | ||||
| Cabinet Material | 1.0 mm Thick Cold Rolled Steel with Epoxy Resin Coating | ||||
| Fan | Integrated Fan 220V, 138W, 250mm Diameter | ||||
| Filter | High Efficiency Filter Technical Parameters | ||||
| Voltage | 220V / 50HZ | ||||
Frequently Asked Questions
What is the difference between ULPA and HEPA filters?
The ULPA series utilizes ultra-high efficiency filters (99.999% efficiency), while the HEPA series employs high-efficiency filters (99.995% efficiency). Both are excellent, but ULPA offers a slightly higher level of purity.
What is the precision of the downward airflow control?
The precision of the downward airflow control is 0.015 m/s, which ensures uniformity and stability of airflow to maintain sterility in the work area.
What sizes are available for the biosafety cabinet?
The YR06545 model is available in various sizes to accommodate different laboratory needs, ensuring versatility for users.
What cleanliness level does the cabinet guarantee?
The cabinet guarantees level 5 of the international standard ISO14644.1 (equivalent to US Federal 209E Class 100), which is a stringent requirement for sensitive environments.
What are the advantages of this biosafety cabinet?
Advantages include dual filtration, superior safety with negative pressure design, optimized airflow, high-performance German motor, and durable construction materials.
What are the disadvantages associated with this cabinet?
Disadvantages include environmental requirements that must be maintained between 10 and 30°C with relative humidity below 70%, considerable shipping weight, and limitations on airflow systems.
Pros and Cons
Pros:
- Dual filtration: utilizes external HEPA filters and ULPA/HEPA descending filters, ensuring up to 99.999% efficiency.
- Superior safety with negative pressure design preventing leaks, protecting operators and the environment.
- Optimized design for airflow uniformity with a reasonable duct.
- High-performance German motor for low consumption and high air volume.
- Durable construction with corrosion-resistant cold-rolled steel and epoxy resin surface treatment.
Cons:
- Environmental requirements must be maintained within 10-30°C with humidity below 70%.
- Shipping weight is considerable, ranging from 138 kg to 198 kg, complicating transport and installation.
- Flow limitations, as 30% of the air is external exhaust, requiring an escape ventilation system.
Field Usage
The Class II Type A2 biosafety cabinet is essential for handling biological agents of low to moderate risk, such as viruses, bacteria, and cell cultures that require biosecurity. It is the standard option in microbiology laboratories, hospitals, and biotechnological and pharmaceutical research centers where protection of products, personnel, and the environment is critical. Its vibration control capability (mean wave: 3 μm) and stable airflow are vital for delicate experiments.
Recommendations
To ensure longevity and maximum safety, it is recommended to:
- Conduct regular maintenance on filters and verify the calibration of the imported sensor.
- Ensure that the working environment meets temperature (10-30°C) and humidity (below 70%) requirements.
- Periodically check the average entry flow speed (0.53 m/s to 0.56 m/s) and the downward airflow speed (average 0.35 m/s) to ensure the effectiveness of negative pressure protection.
- Utilize heavy-duty wheels for initial positioning and ensure stability before use.
For more information or to request a quote, do not hesitate to reach out.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.